SPECIFICATIONS :
- Insulation test range:
- 1507: 0.01 MΩ to 10 GΩ
- 1503: 0.1 MΩ to 2000 MΩ
- Insulation test voltages:
- 1507: 50 V, 100 V, 250 V, 500 V, 1000 V
- 1503: 500 V, 1000 V
- Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio (only available on the1507)
- Make repetitive tests simple and easy with the 1507’s Compare (Pass/Fail) function (only available on the 1507)
- Repetitive or hard-to-reach testing is easy with the remote test probe
- Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
- Auto-discharge of capacitive voltage for added user protection
- AC/DC voltage: 0.1 V to 600 V
- 200 mA Continuity
- Resistance: 0.01 Ω to 20.00 kΩ
- Save battery power with auto power off
- Read measurements easily with large, backlit display
- CAT IV 600 V overvoltage category rating for added user protection
- Remote probe, test leads, probes and alligator clips included with each tester
- Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
- Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
- One year warranty
|
|
|
|
|
| AC/DC Voltage Measurement |
| Accuracy |
| Range |
600.0 V |
| Resolution |
0.1 V |
| 50 Hz to 400 Hz ± (% of Rdg + Digits) |
± (2 % + 3) |
|
| Input impedance |
|
| Common mode rejection ratio (1 kΩ unbalanced): |
| |
> 60 dB at dc, 50 or 60 Hz |
|
| Overload Protection |
|
| Earth bond resistance measurement |
| Range/Resolution |
| 20.00 Ω |
0.01 Ω |
| 200.0 Ω |
0.1 Ω |
| 2000 Ω |
1.0 Ω |
| 20.00 kΩ |
0.01 kΩ |
|
| Accuracy |
|
| Overload Protection |
|
| Open Circuit Test Voltage |
|
| Short circuit current |
|
| Insulation specifications |
| Measurement Range |
| 1507: |
0.01 MΩ to 10 GΩ |
| 1503: |
0.01 MΩ to 2000 MΩ |
|
| Test voltage |
| 1507: |
50 V, 100 V, 250 V, 500 V, 1000 V |
| 1503: |
500 V, 1000V |
|
| Test Voltage Accuracy |
|
| Short circuit current |
|
| Auto Discharge |
| |
Discharge time < 0.5 second for C = 1 µF or less |
|
| Live circuit indicator |
| |
Inhibit test if terminal voltage > 30 V prior to initialization of test |
|
| Maximum Capacitive Load |
| |
Operable with up to 1 µF load |
|
| Measure Accuracy: |
| 50 V: |
±(3 % + 5) |
| 100 V: |
±(3 % + 5) |
| 250 V: |
±(1.5 % + 5) |
| 500 V: |
±(1.5 % + 5) |
| 1000 V: |
±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ |
|
| General Specifications |
| Maximum voltage applied to any terminal: |
|
| Storage Temperature |
| |
-40 °C to 60 °C (-40 °F to 140 °F) |
|
| Operating Temperature |
| |
-20 °C to 55 °C (-4 °F to 131 °F) |
|
| Temperature Coefficient |
| |
0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) |
|
| Relative Humidity |
| |
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) |
| |
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) |
| |
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) |
|
| Vibration |
| |
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |
|
| Shock |
| |
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) |
|
| Electromagnetic compatibility: |
| |
In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) |
|
| Safety |
| |
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) |
|
| Certifications: |
| |
CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition |
|
| Batteries |
| |
Four AA batteries (NEDA 15A or IEC LR6) |
|
| Battery Life |
| Insulation test use: |
Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
| Resistance measurements: |
Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. |
|
| Size |
| |
5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) |
|
| Weight |
|
| IP Rating |
|
| Altitude |
| Operating: |
2000 m CAT IV 600 V, 3000 m CAT III 600 V |
| Non-operating (storage): |
12,000 m |
|
| Over-range capability: |
|
| Included accessories: |
| |
TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe |
|
|
|
|
|