Specifications:
- Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured.
- 12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis.
- One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory.
- Direct communication with PC via USB cable
- Built-in Input / Output Function of external signal enables the signal transmission to alarms.
- 2-way power supply by AC and Battery, and Nickel hydrogen battery usable with rechargeable function.
- Pull / Insert of CF card possible whenever on recording under the function of memory backup device.
- Can monitor insulation at leakage current by using optional leak clamp sensors.
- Built-in Print Screen Function enables to record display screen (Records 512 screens by using CF card: 1 screen 40KB).
- Can display Waveform and Vector, and can confirm the wiring connection, too.
- Complies fully with International Safety Standards IEC 61010-1 CAT.III 600V.
-
• Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems • Voltage, Current, Power Factor and Frequency measurements • Power analysis (Active, Apparent and Reactive power) • Energy analysis (Active, Apparent and Reactive power) • Active power accuracy: ±0.3%rdg±0.2%f.s. • Automatic wiring check function to prevent incorrect connections • Large memory capability (2GB) using built-in SD card interface • Real time & remote measurements using Android application • synchronous measurements between two units of KEW 6305 • Wide selection of clamp sensors allow measurements from 0.1A to 3000A • The instrument automatically recognizes what kind of clamp sensor is connected to it • Windows software for data analysis and setting via USB port or Bluetooth Free Android software "KEW smart 6305" is available
on "Google Play Store" (*)- Supporting Android ver. 2.2 - 4.4
- WVGA (800 × 480) resolution or higher


(*) Please search "KEW Smart" in Google Play Store.
Communication charge may be incurred separately to download application.



















Wiring connections 


1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W 






















Measurements 


Voltage, Current, Frequency, Active power 






















Parameters 


Apparent power, Reactive power, Active energy, Apparent energy,
Reactive energy, Power factor (cos θ), Neutral current






















Voltage : 






























Ranges [RMS] 


150.0 / 300.0 / 600.0V 




























Allowable input 


10~110% of rating range 




























Display ranges 


5~130% of each range 




























Accuracy 


±0.2%rdg±0.2%f.s. (sine wave, 45~65Hz) 
























Current : 






























Ranges [RMS] 


8128 ( 50A type ) : 1.000 / 5.000 / 10.00 / 25.00 / 50.00A / auto 8127 ( 100A type ) : 2.000 / 10.00 / 20.00 / 50.00 / 100.0A / auto 8126 ( 200A type ) : 4.000 / 20.00 / 40.00 / 100.0 / 200.0A / auto 8125 ( 500A type ) : 10.00 / 50.00 / 100.0 / 250.0 / 500.0A / auto 8124 ( 1000A type ) : 20.00 / 100.0 / 200.0 / 500.0 / 1000A / auto 8130 ( 1000A type ) : 20.00 / 100.0 / 200.0 / 500.0 / 1000A / auto 8129 ( 3000A type ) : 300.0 / 1000 / 3000A 




























Allowable input 


10~110% of each range 




























Display ranges 


1~130% of each range 




























Accuracy 


±0.2%rdg±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45~65Hz)
(*) +1%f.s. at the lowest range
























Crest factor 


Voltage: up to 2.5, Current: up to 3.0 (with 90% fs or less) 






















Active power accuracy 


±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor
(*) +1%f.s. when the lowest current ranges is selected.






















Effect of power factor 


Active power: ±1.0%rdg cos θ=±0.5 (PF=1) 






















Frequency meter range 


40.0~70.0Hz 






















Frequency meter accuracy 


±3dgt 






















Accuracy precondition 


PF=1, Sine wave, 45~65Hz, 23ºC±5ºC 






















Display update period 


1 second 






















Operating temperature and humidity range 


0~+50ºC, less than 85%RH (without condensation) 






















Storage temperature and humidity range 


-20~+60ºC, less than 85%RH (without condensation) 






















PC communication interface 


USB, Bluetooth 






















PC card interface 


SD card (2GB) 






















Applicable standards 


IEC 61010-1 CAT.III 600V 






















Power supply (AC Line) 


AC100~240V±10% (50/60Hz) 






















Power supply (DC battery) 


LR6 or Ni-MH (HR-15-51) ×6 (Battery charger not included),
Battery life approx. 15h (LR6)






















Power consumption 


10VA (max.) 






















Dimension 


175(L)×120(W)×65(D) mm 






















Weight 


Approx. 800g (including batteries) 






















Accessories 


7141B (Voltage test lead set: 4pcs)
7148 (USB cable)
7170 (Power cord)
9125 (Carrying case)
8326-02 (SD card 2GB)
KEW WINDOWS (PC Software)
Battery (LR6)×6
Quick manual
Calibration certificate






















Optional 


8124, 8125, 8126, 8127, 8128 (Clamp sensor)
8129/8130 (Flexible clamp sensor)
8312 (Power supply adaptor)
9132 (Magnetic carrying case)












Set Model 


KEW 6305-01 KEW 6305 × 1 
MODEL 8125 × 3 7141B (Voltage test lead set: 4pcs) × 1 7148 (USB cable) × 1 7170 (Power cord) × 1 8326-02 (SD card [2GB]) × 1 9125 (Carrying case) × 1 PC Software × 1 Battery × 6 Quick manual × 1 Calibration certificate
View more about Kyoritsu 6305 Power Meter on main site